ABB CONTACTOR, 140A, 120V COIL, 1NO 1NC AF140-30-11-12

$ 158.39

Availability: 83 in stock
  • Custom Bundle: No
  • MPN: AF140-30-11-12
  • Condition: New
  • Brand: ABB

    Description

    Number of Main Contacts NO:
    3
    Number of Main Contacts NC:
    0
    Number of Auxiliary Contacts NO:
    1
    Number of Auxiliary Contacts NC:
    1
    Rated Operational Voltage:
    Main Circuit 690 V
    Rated Frequency (f):
    Main Circuit 50 / 60 Hz
    Conventional Free-air Thermal Current (I
    th
    ):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 200 A
    Rated Operational Current AC-1 (I
    e
    ):
    (690 V) 40 °C 200 A
    (690 V) 70 °C 160 A
    Rated Operational Current AC-3 (I
    e
    ):
    (415 V) 55 °C 140 A
    (440 V) 55 °C 140 A
    (500 V) 55 °C 130 A
    (690 V) 55 °C 80 A
    (380 / 400 V) 55 °C 140 A
    (220 / 230 / 240 V) 55 °C 140
    Rated Operational Current AC-3e (I
    e
    ):
    (415 V) 60 °C 140 A
    (440 V) 60 °C 140 A
    (500 V) 60 °C 130 A
    (690 V) 60 °C 80 A
    (380 / 400 V) 60 °C 140 A
    (220 / 230 / 240 V) 60 °C 140 A
    Rated Operational Power AC-3 (P
    e
    ):
    (415 V) 75 kW
    (440 V) 90 kW
    (500 V) 90 kW
    (690 V) 75 kW
    (380 / 400 V) 75 kW
    (220 / 230 / 240 V) 37 kW
    Rated Operational Power AC-3e (P
    e
    ):
    (415 V) 75 kW
    (440 V) 90 kW
    (500 V) 90 kW
    (690 V) 75 kW
    (380 / 400 V) 75 kW
    (220 / 230 / 240 V) 37 kW
    Rated Breaking Capacity AC-3:
    8 x Ie AC-3
    Rated Breaking Capacity AC-3e:
    8.5 x Ie AC-3e
    Rated Making Capacity AC-3:
    10 x Ie AC-3
    Rated Making Capacity AC-3e:
    12 x Ie AC-3e
    Short-Circuit Protective Devices:
    gG Type Fuses 315 A
    Rated Short-time Withstand Current Low Voltage (I
    cw
    ):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
    Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
    Maximum Electrical Switching Frequency:
    (AC-1) 300 cycles per hour
    (AC-2 / AC-4) 150 cycles per hour
    (AC-3) 300 cycles per hour
    Rated Operational Current DC-1 (I
    e
    ):
    (110 V) 2 Poles in Series, 40 °C 160 A
    (220 V) 3 Poles in Series, 40 °C 160 A
    Rated Operational Current DC-3 (I
    e
    ):
    (110 V) 2 Poles in Series, 40 °C 160 A
    (220 V) 3 Poles in Series, 40 °C 160 A
    Rated Operational Current DC-5 (I
    e
    ):
    (110 V) 2 Poles in Series, 40 °C 160 A
    (220 V) 3 Poles in Series, 40 °C 160 A
    Rated Insulation Voltage (U
    i
    ):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
    Rated Impulse Withstand Voltage (U
    imp
    ):
    Main Circuit 8 kV
    Mechanical Durability:
    5 million
    Maximum Mechanical Switching Frequency:
    300 cycles per hour
    Coil Operating Limits:
    (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
    Rated Control Circuit Voltage (U
    c
    ):
    50 Hz 48 ... 130 V
    60 Hz 48 ... 130 V
    DC Operation 48 ... 130 V
    Coil Consumption:
    Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A
    Holding at Max. Rated Control Circuit Voltage DC 2.5 W
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A
    Pull-in at Max. Rated Control Circuit Voltage DC 150 W
    Operate Time:
    Between Coil De-energization and NO Contact Opening 37 ... 47 ms
    Between Coil Energization and NO Contact Closing 25 ... 55 ms
    Connecting Capacity Main Circuit:
    Flexible 2 x 10 ... 70 mm²
    Rigid Cu-Cable 2 x 10 ... 95 mm²
    Connecting Capacity Auxiliary Circuit:
    Flexible with Ferrule 2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
    Flexible 1x0.75 ... 2.5 mm²
    Solid 2 x 1 ... 4 mm²
    Stranded 1 x 1 .... 4 mm²
    Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
    Terminal Type:
    Double Clamp