-40%

ABB AF40-30-11-13 AF Contactor, 1SBL347001R1311

$ 58.71

Availability: 34 in stock
  • MPN: 1SBL347001R1311
  • Number of Poles: 3-Pole
  • Coil Voltage: 250 V
  • Number of Phases: 3
  • Condition: New – Open box
  • Current Type: AC/DC
  • Country/Region of Manufacture: Czech Republic
  • NEMA Size: Size 2
  • Mounting Style: DIN Rail Mount
  • Brand: ABB
  • Custom Bundle: No

    Description

    ABB AF40-30-11-13 AF Contactor, 1SBL347001R1311
    Magnetic contactor - ABB (AF series) - AF40-30-11-13 100-250V 50/60HZ-DC CONTACTOR - 3-poles (3P) - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Rated current 40A (AC-3) - Rated power 18.5kW / 30HP - Control coil voltage 100Vac-250Vac (110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac) (50Hz/60Hz) / 100-250Vdc (110Vdc / 220Vdc) - with 1NO+1NC aux. contacts - Screw-clamp connections - Mounting on plate
    Dimensions
    Product Net Width:67 mm
    Product Net Depth / Length:111 mm
    Product Net Height:125.5 mm
    Product Net Weight:0.99 kg
    Technical
    Number of Main Contacts NO:3
    Number of Main Contacts NC:0
    Number of Auxiliary Contacts NO:1
    Number of Auxiliary Contacts NC:1
    Rated Operational Voltage:Auxiliary Circuit 690 V
    Main Circuit 690 V
    Rated Frequency (f):Auxiliary Circuit 50 / 60 Hz
    Main Circuit 50 / 60 Hz
    Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A
    acc. to IEC 60947-5-1, q = 40 °C 16 A
    Rated Operational Current AC-1 (Ie):(690 V) 40 °C 70 A
    (690 V) 60 °C 60 A
    (690 V) 70 °C 50 A
    Rated Operational Current AC-3 (Ie):(415 V) 60 °C 40 A
    (440 V) 60 °C 40 A
    (500 V) 60 °C 35 A
    (690 V) 60 °C 25 A
    (380 / 400 V) 60 °C 40 A
    (220 / 230 / 240 V) 60 °C 40 A
    Rated Operational Current AC-3e (Ie):(415 V) 60 °C 40 A
    (440 V) 60 °C 40 A
    (500 V) 60 °C 35 A
    (690 V) 60 °C 25 A
    (380 / 400 V) 60 °C 40 A
    (220 / 230 / 240 V) 60 °C 40 A
    Rated Operational Power AC-3 (Pe):(400 V) 18.5 kW
    (415 V) 22 kW
    (440 V) 22 kW
    (500 V) 22 kW
    (690 V) 22 kW
    (380 / 400 V) 18.5 kW
    (220 / 230 / 240 V) 11 kW
    Rated Operational Power AC-3e (Pe):(415 V) 22 kW
    (440 V) 22 kW
    (500 V) 22 kW
    (690 V) 22 kW
    (380 / 400 V) 18.5 kW
    (220 / 230 / 240 V) 11 kW
    Rated Operational Current AC-15 (Ie):(500 V) 2 A
    (690 V) 2 A
    (24 / 127 V) 6 A
    (220 / 240 V) 4 A
    (400 / 440 V) 3 A
    Rated Short-time Withstand Current Low Voltage (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
    for 0.1 s 140 A
    for 1 s 100 A
    Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
    Maximum Electrical Switching Frequency:(AC-1) 600 cycles per hour
    (AC-15) 1200 cycles per hour
    (AC-2 / AC-4) 150 cycles per hour
    (AC-3) 1200 cycles per hour
    (DC-13) 900 cycles per hour
    Rated Operational Current DC-13 (Ie):(24 V) 6 A / 144 W
    (48 V) 2.8 A / 134 W
    (72 V) 1 A / 72 W
    (110 V) 0.55 A / 60 W
    (125 V) 0.55 A / 69 W
    (220 V) 0.27 A / 60 W
    (250 V) 0.27 A / 68 W
    (400 V) 0.15 A / 60 W
    (500 V) 0.13 A / 65 W
    (600 V) 0.1 A / 60 W
    Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
    acc. to UL/CSA 600 V
    Rated Impulse Withstand Voltage (Uimp):6 kV
    Maximum Mechanical Switching Frequency:3600 cycles per hour
    Rated Control Circuit Voltage (Uc):50 Hz 100 ... 250 V
    60 Hz 100 ... 250 V
    DC Operation 100 ... 250 V
    Operate Time:Between Coil De-energization and NC Contact Closing 19 ... 105 ms
    Between Coil De-energization and NO Contact Opening 17 ... 100 ms
    Between Coil Energization and NC Contact Opening 38 ... 95 ms
    Between Coil Energization and NO Contact Closing 42 ... 100 ms
    Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
    Mounting by Screws (not supplied):2 x M4 or 2 x M6 screws placed diagonally
    Connecting Capacity Main Circuit:Flexible with Ferrule 1/2x 4 ... 35 mm²
    Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
    Rigid 1/2x 6 ... 3 5 mm²
    Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
    Rigid 1/2x 1 ... 2.5 mm²
    Connecting Capacity Control Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
    Rigid 1/2x 1 ... 2.5 mm²
    Wire Stripping Length:Main Circuit 16 mm
    Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
    Terminal Type:Screw Terminals
    Technical UL/CSA
    NEMA Size:2
    Continuous Current Rating NEMA:45 A
    Horsepower Rating NEMA:(115 V AC) Single Phase 3 Hp
    (200 V AC) Three Phase 10 Hp
    (230 V AC) Single Phase 7-1/2 Hp
    (230 V AC) Three Phase 15 Hp
    (460 V AC) Three Phase 25 Hp
    (575 V AC) Three Phase 25 Hp
    General Use Rating UL/CSA:(600 V AC) 60 A
    Horsepower Rating UL/CSA:(120 V AC) Single Phase 3 hp
    (200 ... 208 V AC) Three Phase 10 hp
    (220 ... 240 V AC) Three Phase 15 hp
    (240 V AC) Single Phase 7-1/2 hp
    (440 ... 480 V AC) Three Phase 30 hp
    (550 ... 600 V AC) Three Phase 40 hp
    Tightening Torque UL/CSA:Auxiliary Circuit 11 in·lb
    Control Circuit 11 in·lb
    Main Circuit 35 in·lb
    Environmental
    Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
    Close to Contactor without Thermal O/L Relay -40 ... 70 °C
    Close to Contactor for Storage -60 ... +80 °C
    Climatic Withstand:Category B according to IEC 60947-1 Annex Q
    Maximum Operating Altitude Permissible:Without Derating 3000 m
    Resistance to Vibrations acc. to IEC 60068-2-6:5 ... 300 Hz 3 g closed position / 3 g open position
    Resistance to Shock acc. to IEC 60068-2-27:Closed, Shock Direction: A 25 g
    Closed, Shock Direction: B1 25 g
    Closed, Shock Direction: B2 15 g
    Closed, Shock Direction: C1 25 g
    Closed, Shock Direction: C2 25 g
    Open, Shock Direction: B1 5 g
    International buyers – please note: Import duties, taxes, and charges aren't included in the item price or postage cost. These charges are the buyer's responsibility."
    "Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying